Guidelines for reinforced cement concrete design

This construction video provides detailed guidelines for designing reinforced cement concrete with adherence to the Indian National Building Code (IS 456 – 2000).
This code is designed for general structural application of plain and reinforced concrete. This code employs the limit state design approach along with working stress design approach. It provides wide-ranging information on the different characteristics of concrete.

It comprises of the following five sections and eight annexures:
• Section 1: General
• Section 2: Materials, Workmanship, Inspection and Testing
• Section 3: General Design Considerations
Section 4: Special Design Requirements for Structural Members and Systems
• Section 5: Structural Design (Limit State Method)
By going through this video, you will learn how to design various types of structural components like beam, column, slab, footing etc. as well as objective of structural designing.
The video briefly explains the following topics :-
1. Purpose of structural designing and designing method
2. Variation among plain concrete and reinforced concrete
3. Fundamental characteristics of concrete as follow
a. Grade of concrete
b. Characteristics strength of concrete
c. Modulus of elasticity of concrete
d. Creep and shrinkage
e. Longevity
f. Tensile strength
4. Fundamental properties and categories of reinforced steel
a. Grade and categories of steel
b. Yield strength of mild steel and HYSD Bars

Watch the following video for online demonstration.



Read continue

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co

~~~~~~~~~~~~~~~~~~~~~~~~

Friday, June 23, 2017

Different types of clear cover in reinforcement concrete

This construction video tutorial provides brief instructions on how to arrange clear cover in different areas in proper quantities in reinforcement concrete. It is dependent on the exposure condition and fire resistance.
Clear Cover stands for the minimum distance among the surface of embedded reinforcement and the exterior surface of the concrete (ACI 130). The depth of clear cover is calculated with a cover meter.
Given below the details of clear cover :-
For water retaining structures – The clear cover should vary from 20 mm to 30 mm
For flat slab – The clear cover should be 20 mm
For slab – The clear cover will be 15 mm
For column – The clear cover should have been 40 mm
For strap beam – The clear cover should be 50 mm

For raft foundation at bottom – The clear cover should be 75 mm
For shear wall – The clear cover should be 25 mm
For footing – The clear cover should be 50 mm
For staircase – The clear cover should be 15 mm