adsense analytic

Showing posts with label Concrete Column Design. Show all posts
Showing posts with label Concrete Column Design. Show all posts

Tuesday, July 25, 2017

KaderColumn – A useful construction program for column analysis

KaderColumn is a powerful construction program that is created for reinforced concrete tied short columns.
It can be used to create the designs of columns based on up to eleven cases of loading comprising of axial load and bending moment implemented about the maximum principle axis.
The program allows to build up the column strength interaction diagram (Bending moment-Axial load curve) out of the input data of the cross-section and verify whether all input cases of loading are situated inside the design curve. If the input data of the cross-section is insufficient, the program enhances them to commence from the Min. Roh to the cross-sectional dimensions unless all input cases of loading remain inside the design curve. The program provides proposition for setting ties properly and draws them.
Features:
• It is very user-friendly and short.
• It computes and draws the column strength interaction diagram toward a reinforced concrete tied short column having a rectangular (containing rebars at two sides only or at all four sides), square or circular section and depending on axial load and bending moment around the max. principle axis of its cross-section.

• Up to eleven cases of loads (axial load and bending moment) are permissible. The program examines all these cases which should remain inside the column interaction diagram.
• It designs the section and draws by organizing ties in an efficient manner.
• The user will be capable of rectifying the section dimensions, the min. and max. ratio of reinforcement and some other parameters for obtaining the rational section from his point of view.
• The user will be able to save and open the input data file that is already saved by the program.
• The program employs the ultimate strength method for design and abides by the exact ACI 318-02 Code requirements.

To download this construction program, visit the developer’s website www.cadkad.com

KaderColumn – A useful construction program for column analysis


~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~

Friday, June 23, 2017

Different types of clear cover in reinforcement concrete

This construction video tutorial provides brief instructions on how to arrange clear cover in different areas in proper quantities in reinforcement concrete. It is dependent on the exposure condition and fire resistance.
Clear Cover stands for the minimum distance among the surface of embedded reinforcement and the exterior surface of the concrete (ACI 130). The depth of clear cover is calculated with a cover meter.
Given below the details of clear cover :-
For water retaining structures – The clear cover should vary from 20 mm to 30 mm
For flat slab – The clear cover should be 20 mm
For slab – The clear cover will be 15 mm
For column – The clear cover should have been 40 mm
For strap beam – The clear cover should be 50 mm

For raft foundation at bottom – The clear cover should be 75 mm
For shear wall – The clear cover should be 25 mm
For footing – The clear cover should be 50 mm
For staircase – The clear cover should be 15 mm


Read more

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co

~~~~~~~~~~~~~~~~~~~~~~~~


Tuesday, June 6, 2017

How to study column footing drawing for a structure

This construction video offers detailed guidelines on how to check column footing drawing.
Footings stand for structural elements which deliver the loads of column or wall to the elementary soil underneath the structure. Footings are built up to disperse these loads to the soil devoid of surpassing its safe bearing capacity, to resist enormous settlement of the structure to an acceptable limit with the purpose of reducing differential settlement as well as withstanding sliding and overturning.
The settlement is dependent on the depth of the load, nature of soil, and foundation level. If there is differential settlement, the different footings have to be designed in such a manner to settle self-reliantly of each other.

Foundation design comprises of a soil study to set up the most suitable type of foundation and a structural design to find out footing dimensions and necessary amount of reinforcement. As the compressive strength of the soil is normally much weaker as compared to the concrete, the contact area among the soil and the footing is much bigger with regard to that of the columns and walls.

Read Continue

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co

~~~~~~~~~~~~~~~~~~~~~~~~

Tuesday, May 16, 2017

Detail processes for creating the design of RCC Column with foundation

Reinforced Cement Concrete column is a part and parcel of RCC frame structured building.
Reinforced concrete foundations are designed on the basis of column loads and moments at base and the soil data.
It belongs to a vertical member that delivers loads from slab and beam directly to succeeding soil.
The entire building rests on columns. The collapsing of the most of the buildings occurs because of column failure. Beside design errors, substandard construction practice also leads to failure of column. So, it is mostly crucial to have a clear & perfect idea on the construction process of the RCC column.
In order to buildup RCC (Reinforced Cement Concrete) Column, the following four stages of works are essential :-.

1. Column layout work
2. Column reinforcement work
3. Column formwork, and
4. Pouring concrete into column.

To learn the complete process for RCC Column Design with foundation, go through the following link. onlinecivilforum.com

Detail processes for creating the design of RCC Column with foundation

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~