Friday, July 20, 2018

Benefits of post-tensioning concrete slabs in building

Post-tensioned concrete slabs in buildings provide various benefits over reinforced concrete slabs & other structural systems toward both single and multi-level structures. Described below, some of the advantages of the slabs :-

Longer Spans: Longer spans are utilized to lessen the number of columns. It leads to bigger, column free floor areas which significantly enhance the adaptability of application for the structure as well as leads to greater rental returns.

Entire structural cost: The complete cost of materials, labor and formwork which are essential to build up a floor is decreased for spans higher than 7 meters and consequently leads to huge cost savings.

Minimized floor to floor height: Thinner slabs are utilized for the similar imposed loads. The decreased section depths facilitate least building height together with consequent savings in facade costs. As a substitute, toward bigger buildings, it facilitates more floors to be developed inside the original building envelope.

Deflection Free Slabs: Unwanted deflections under service loads are virtually removed.

Water-resistant slabs: Post-tensioned slabs are designed to remain free from cracks and as a result water-resistant slabs should be formed with proper design, detailing and construction. The selection of concrete mix and curing method together with standard workmanship are also very important.

Early formwork stripping: The earlier stripping of formwork and curtailed backpropping requirements facilitate rapid construction cycles as well as fast reprocessing of formwork.

Materials Handling: The decreased material quantities in concrete and reinforcement significantly offer benefit to on-site carnage requirements. The stability of post-tensioning strand is roughly 4 times that of traditional reinforcement. So, the whole weight of reinforcing material is considerably minimized.

Column and footing design: The decreased floor dead loads are applied to create cost-effective design of the reinforcement concrete columns and footings. In multi-storied buildings, decreased column sizes may raise the floor net rentable area.

Benefits of post-tensioning concrete slabs in building


Read more

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~

Thursday, August 24, 2017

How beam and lintel differs as per structural behavior & load carrying system

This construction video tutorial briefly explains the variations among beam and lintel.

Both the beam and lintel are flexural as well as horizontal members and considered as the vital parts of structural system. But these differ according to their structural behavior and load carrying system.
Given below the points of differentiation:-
To gather more information, watch the following construction video

tutorial.




~~~~~~~~~~~~~~~~~~~~~~

Published By
Rajib Dey
www.constructioncost.co

~~~~~~~~~~~~~~~~~~~~~~

Saturday, February 4, 2017

How to place stirrups with proper structural drawings in a column

This construction video is recorded on the topic of how to organize stirrups for a column that contains 12nos of vertical bar. Learn to apply various structural drawings for organizing stirrups.

Stirrup can be defined as follows :-

1. A reinforcement useful for withstanding shear and diagonal tension stresses in a concrete structural member.

2. A steel bar that is curved into a "U" or box shape and arranged perpendicular to, or at an angle to the longitudinal reinforcement, and perfectly anchored.

3. Lateral reinforcement that is developed with separate units, open or closed, or of uninterruptedly wound reinforcement. The word stirrups is generally used with lateral reinforcement in flexural members and the term is linked with lateral reinforcement in vertical compression members.

Concrete beams contain different depth. If the beam contains more depth, the shear strength will be increased. If the depth is insufficient, steel stirrups should be included to enhance the shear strength of the beam. These stirrups generally refer to one piece of steel that is curved into a quadrilateral shape. Generally small diameter steel like #3 and #4 rebar is applied. The stirrup normally covers around the bottom and top bars of the beams.

As the stirrup is built up from two pieces having insufficient lap splice, it is recommended to set up a stirrup simultaneously when the horizontal reinforcement is being set up.


~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
~~~~~~~~~~~~~~~~~~~~~