How to design any one way simply supported slab

In this construction video tutorial, you will learn how to create the design of one way slab (simply supported slab) that is standing on the masonry wall.


You will also gather information on all checks for making design of the slab.
The requirements and materials of the slab are given below :-
Clear span = 3m
Live load = 4000 N/m2
M20 concrete and fe 415 steel are used here.
The calculation is made on the following dimensions :-
A bearing of 120 mm is provided at each end. The distance among centers of bearing = 3+0.12 = 3.12 m
Necessary effective depth = Span/20 x modification factor
= 3120/20 x 1.40 = 112 mm
The bars with 8 mm diameter are arranged with clear cover of 15 mm.
Effective cover = 15 + 4 = 19 mm
Overall necessary depth = 112 + 19 = 131 mm
It is necessary to arrange an overall depth of 135 mm
So, effective depth = 135-19 = 116 mm
The Dead load of the slab will be calculated as follow :-
25 x 135 = 3375 N/m2 (floor finished with C20 mm).
Live load = 4000 N/m2
Therefore, total load = 7855 N/m2
Factor load = Wµ = 1.50 x 7855 = 11782.5 N/m2
To get more details, go through the following video tutorial.
How to design any one way simply supported slab

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~

Monday, April 23, 2018

How to measure prying force in bolted connection

This is another useful construction tutorial from Dr. Chirag Patel. In this video, you will learn how to make detail measurement for "Prying Force" in bolted steel structural connection as well as remove it’s effect.

In a tension or hanger connection, the operative load creates tension in the bolts and the bolts are designed as tension members. If the connected plate is admissible to deform, supplementary tensile forces known as prying forces are developed in the bolts.

In this video example is given for verifying the exact capacity of a D hanger connection based on the following dimension :-
Bolt Diameter = 30 mm
Bolt Grade = 4.6
Dimension of end plate = 230 x 150 mm
Thickness of T-flange = 32 mm
The connection will not collapse if the tension capacity is higher than total load. Here, tension capacity is taken as 200 kN.
To learn the detail calculation process, go through the following video tutorial.