Some useful guidelines to develop a building foundation

While building up a foundation for a building, adequate knowledge is required with some particular steps to make sure that the footings will retain the weight of the building through rest of time.

The purpose of building foundations is to bear the load of the structure as well as disperse the load to the soil in greater cross sectional area. The foundation should have the capacity to resist the load of the structure along with the live loads and environmental factors.

A safety factor is arranged for safety all through the foundation design. The foundation is built up on the basis of the design. Given below, some vital steps, which should be abided by, at the time of constructing & designing building foundation.

1: Survey and Stake Out Footprint - A professional surveyor should execute this step. The surveyor will settle on the exact distances from the property lines. It makes sure that the building will set out perfectly and abide by the code. The corners of the building will be marked with surveyor’s stakes.

Then the surveyor will arrange offset stakes about two feet out from the surveyor’s stakes. The digging for the foundation will start by applying the offset stakes as the guides. It accomodates extra room so the work can be performed on the exterior foundation walls.

2: Excavation - A structural engineer is required to define the depth of the excavation. All surface soils should be eliminated to uncover the soil that is properly compressed to carry the weight of the building.

The depth will differ for each building. The top of the footing should remain underneath the frost line since it resists the concrete from cracking when the freeze-thaw cycle happens in the soil that encircles the building.

3: Footings - A footing stands for a poured concrete pathway that is applied to expand the weight of the building from the foundation walls to the soil. They are larger as compared to the foundation walls that they are supporting and create the perimeter of the building. In some cases, there exist extra footings which are provided inside the perimeter to provide support to the load-bearing walls.

4: Sub Slab - Normally, plumbing lines are arranged from the street to the building’s basement by passing over or even below the footing. It occurs for the buildings which contain their own separate sewage facility or drain field. A poured concrete slab is used to cover these lines.

5: Foundation Drainage System - Subsurface water is preserved and pushed away from the foundation to get rid of pooling water or flooding. The foundation drainage tile is constructed with an incessant run of punched drainage pipes which are implanted in gravel along the foundation of the building. In some areas, a sump pump may also be needed to facilitate accumulating the subsurface water.

To gather knowledge on other steps, go through the following link civilengineersforum.com

Some useful guidelines to develop a building foundation

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~

Saturday, November 18, 2017

How to design reinforced & unreinforced concrete and masonry gravity retaining walls as per Euro & BS codes

MasterKey Retaining Walls Design provides the most extensive program that can be used for creating the design of both reinforced and unreinforced concrete and masonry gravity retaining walls as per Eurocode 7, BS 8002, BS 8110, CP2 IS 325 and BS 5628 Part1 and Part2. Highways design by adhering to BD 30/87 & BD37/01 is also comprised.

The users can easily use MasterKey Retaining Walls with a short learning curve.


With it’s collaborative nature, it is possible to instantly view the effects of inserting loads, piers, ties and props, rectifying reinforcement as well as the wall geometry or soil properties. MasterKey Retaining Walls offers you complete control over the design method, allowing you to improve the efficiency of the wall.
• Design Codes: British, Irish & Eurocode design
• Concrete retaining wall design
• Masonry retaining wall design
• Cavity, bed-joint and pocket reinforcement in masonry walls
• Design to Eurocode 7, BS 8002 or CP2
• Design to Highways BD 30/87 & BD 37/01
• Stiffened and unstiffened walls including buttressed and counterfort walls
• Layered soil modelling
• Water table and horizontal surge force
• Cohesive and granular soils
• Sloped or stepped front and back faces
• Upstand above top of soil
• At rest earth pressure
• Multiple props, ties and spring supports
• Line loads on wall, base and embankment
• Partial distributed surcharges
• Exports DXF details
• Exports details to MasterRC for AutoCAD
• Schedules using the MasterRC Scheduler
In order to download a full functioning 30-days trial version, click on the following link masterseries.com

~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~

Monday, November 14, 2016

How to use Tekla Structure 2016 for bridge pier reinforcement

This construction video briefly shows how to use Tekla Structure 2016 to perform bridge pier reinforcement.

Concrete piers stand for vertical structural elements that support the weight of a building or structure. The role of the concrete piers is similar to the table legs. If they are designed properly, and arranged on solid ground or to a depth that the friction on the sides of the pier is exceeding the load placed on the pier, the piers and the structure will be immovable.

Most concrete piers applied over the average home for a deck or other structures are generally lower than 24 or so inches in diameter at the base of the pier. As the pier increases and out of the ground, it can be minimized in size to as small as 10 inches in diameter. The bottom of the pier should always remain under the frost line in the area.

The bottom of the pier should be broader as compared to the top. The wider base facilitates allocating the weight of the structure over more soil. Thus the design becomes stable enough.


~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
~~~~~~~~~~~~~~~~~~~~~