The Good and Bad of Precast Piles

The most common type of them, a precast concrete pile is a deep foundation used to transfer loads from a upper, soft layer of soil to a hardar, capable lower layer. They can be rectangular, square, round or polygonal in shape. Extra reinforcements are provided in the concrete so as to provide support for the forces received before the instalent.

The precast concrete piles are constructed in a casting yard. Then they are transported to the required location and installed as necessary.

They are constructed by pouring the concrete in a conventional reinforcement cage. This has several steel bars in horizontal and vertical positions, held together by individual or spiral ties.

Types of Precast Concrete Piles

There are two main categories into which we can divide:

1. Driven Precast Concrete Piles

It is precast in a construction yard and then hammered into the soft ground at the target location. At most they can go up to 40 feet deep.

2. Bored Precast Concrete Piles

After they are made in the construction yard, they are transferred to the target location. The location already has boreholes for the piles; they are just lowered into these holes. Any space remaining between the bore hole and the pile is grouted.

Difference between the Driven and Bored Precast Concrete Piles

1. Bored piles are better in urban locations since they avoid the noise and vibrations caused by vibrators.
2. The bore hole can be as deep as necessary, or as deep as the machinery can go. Unlike driven piles, the bore piles have no depth limit.
3. Driven piles can be established quickly.
4. Driven piles can be easily used underwater.


The Good and Bad of Precast Piles

~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co

~~~~~~~~~~~~~~~~~~~~~~~~~~

Saturday, January 11, 2020

Thumb Rules to Follow While Designing Columns

Columns are essential support structures that are almost inevitably used in any construction projects. From ancient times, columns have been an indispensable part of erecting buildings, them being one of the most important load-bearing members. Obviously, one needs to be careful while designing such important structures.
As per the construction sciences and technologies, there are many rules applicable to specific columnar structures. However, there are some few basic rules of column designing that all engineers can keep in mind while designing most types of columns and similar vertical supports.
Today, we will discuss these important thumb rules of column design in this article. Needless to say, columns need to be designed keeping in mind the total amount of forces acting on the structure. But also, keeping these basic guidelines in mind can prevent architects and engineers from making silly mistakes.
Rule 1: Essentially, the size of the columns would depend upon the total amount of forces acting on the column. In short you can consider this as the total load on a column. This will make or break the column, so you need to be ensuring that your columns design can withhold this entire load and anything else that may come later.
That is, the total load on a column may be not only the weight of the structure that it bears, but also the movable materials that structure will bear. For example, while designing a multi-storied godown, you will need to care about not only the weight of the floor and the walls and the roof, but more also, the weight of the goods that are going to be stored on that floor. This can get pretty great in case of solid materials.
Thumb Rules to Follow While Designing Columns
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Saturday, May 11, 2019

How to perform audit of old structures

There exist several types of public buildings with over 30 years lifespan. The stability of these buildings is decreased significantly owing to decay in materials.

On the basis of the yearly tests conducted on each public building, the weaker buildings having age over 30 years should be detected and the Assistant Executive Engineer level Officer of the related department should dispatch the list to the superior officer of the level.

Then, an inspection at the level of superintending Engineer/EE should be performed for all such building and an extensive structural audit should be carried out.

The related department should hand over the structural audit to an accredited Institution / agency and the details of which are provided below:

Usually, the Structural Audit should be performed with the following steps:

Step 1: The Architectural and Structural plans of the building are important. There should be detailed structural calculations along with assumptions for the structural design.

Step 2: When the Architectural plans and Structural plans do not exist, the similar should be arranged on the basis of site observations.

Step 3: A building should be examined thoroughly as follow :-

1. Any settlement in the building.
2. Cracks found in columns, beams and slabs.
3. Pictures of concrete disintegration and exposed steel reinforcements are useful.
4. Slight tapping with a hammer can disclose decay in concrete and wooden beams.


5. Erosion in reinforcement.
6. Status of Balconies – sagging, deflection, cracks.
7. Status of Architectural features.
8. Cracks in walls specifying swelling in R.C.C members or identification of erosion.
9. Leakages from terrace & Toilet blocks.
10. Leakages & dampness in walls which lead to cracks and corrosion.
11. Status of repairs & last repaired date.
12. What section of the structure was repaired?
13. Who was the Agency?
14. How much was incurred for repairs?
15. Are sanctioned Building plans available?


Step 4: Formulation of Audit Report:
Depending on the inspection on building, the Audit Report should be arranged.


Step 5: Tests Suggested:
It is vital that different types of tests are performed in the old buildings to get an idea about spreading of corrosion, distress and loss of strength in concrete & steel.


Step 6: Point out the major areas and repair them accordingly.

How to perform audit of old structures

Read more
~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~

Wednesday, November 23, 2016

Advantages Of Truss Mesh Reinforcement For Brick Wall

Truss mesh reinforcement is essential for developing masonry wall. Truss mesh reinforcements are implanted into the horizontal mortar joints of masonry walls and constant with the wall length.

Reinforces various types of masonry walls

Considerably lowers the cracking that may happen due to thermal stresses

Improves resistance capacity against penetration of water, because cracks are well organized

Improves lateral flexural strength

Enhances elasticity

Enhances performance of masonry walls under different stresses

Specifications

Existing Materials: hot dipped galvanized, electro galvanized or stainless steel.
Wire diameter:1.8mm - 2.0mm.
Weight: 2kg - 10kg.
Length: 3 meters long, the space distance is 40cm
Width 5cm, 10cm, 15cm, 20cm ,25cm, 30cm.


Advantages Of Truss Mesh Reinforcement For Brick Wall

~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
~~~~~~~~~~~~~~~~~~~~~

Tuesday, October 4, 2016

Details of Machine Foundation

The design of machine foundation is carried out for evaluating vibration characteristics of the foundation system cautiously. The machine manufacturer supplies the appropriate data essential for the design and development of the machine foundation of machine before creating the design. All parts of machine foundation are created for extreme stresses because of the poorest combination of vertical loads, torque, longitudinal and transverse forces, stresses because of dissimilarity in temperature and the foundation dead load. In case, the machine foundation layout is partially constructed with beam and column construction, straight bars are placed both at top and bottom of the beams and the gaping of the stirrups should be nearby. The primary foundation block must contain the calculated thickness and should be reinforced both at top and bottom, although the reinforcements are not compulsory from design considerations.

General standards of machine foundation design are provided below :-

There should be adequate mass of the foundation block to absorb vibrations and as well as withstand resonance among the machine and the adjoining soil. This is possible with the increased weight of foundation block according to the power of the engines. It is recommended that for every break horse power of multicylinder engines, a lowest 725 kg. weight of foundation should be arranged for gas engines, 565 kg. for diesel engines and 225 kg. for steam engines. This value is raised by 40 to 60% for the single cylinder engines. As a thumb rule, the weight of the foundation must be minimum 2½ times the weight of the entire machine.

To get rid of the variation in settlement, the dimension of the machinefoundation should be perfect so that the subsequent force move through the centre of gravity of the base contact area as a result of the weight of the machine and the weight of the foundation.

The foundation should have been solid enough to maintain required strength as the smallest deflection of foundation can lead to significant bearing troubles.

There should be a gap around the machine foundation so that the vibration is not delivered from the machine to the adjacent parts of the building to separate it from the adjoining parts of the building.

Overhanging cantilevers should not be used in most cases. If it is not possible, they should have been designed for stability and hardness against vibrations.(6) All units of machine foundation are arranged with reinforcement passing both ways along the surface of the concrete block. The concrete cover to the reinforcement must not be below than 75 mm at the bottom, 50 mm on sides and 40 mm at the top. For foundation developed with steam turbo-generators, cover for the reinforcement at bottom, side and top of base slab must not be below 100 mm.

The amount of reinforcement in foundation units should not be below 2 kg per cu. m of concrete toward impact type or reciprocating type of machines, 50 kg per cu. m of concrete for rotary type of machines and 100 kg per cu. m of concrete for steam turbo generators.

M 150 to M 200 grade of concrete should be applied in the foundations and mostly the-entire block should be concreted in one process devoid of construction joints.