Some vital guidelines for measuring staircase dimensions and designs

A staircase mainly includes a series of steps which involve a tread (the horizontal portion, where the foot stands) and a riser (the vertical portion).
In every step, there are one or more landings, handrails, and a small nosing. The latter obtrudes from the tread over the lower step, facilitating to raise its size devoid of inclusion of centimeters to the overall dimensions of the staircase.
By using the following formula, find out the exact dimensions of a convenient and efficient staircase in accordance with its use.
2 Risers + 1 Tread = 63-65 cm
The required space to attain these optimal dimensions is unavailable sometimes, but it's suggested to approach them as much as possible.
A schematic illustration of a steep and low-transit staircase.
(2 x 21) + (1 x 21) = 63 cm
A schematic illustration of an optimal staircase.
(2 x 18) + (1 x 28) = 64 cm
A schematic illustration of a loose staircase, desirably for exterior application.
(2 x 13) + (1 x 39) = 65 cm
Sample measurement of a staircase that should be 2.60 meters high.
1. Workout the required number of steps - Assume an ideal riser of 18 cm, the height of the space is divided with the height of each step. The result should always be rounded up:
260/18 = 14.44 = 15 steps
2. Workout the height of every riser - The height of the space is divided with the number of steps already acquired:
260/15 = 17.33 cm height for each riser.
3. Workout the width of the tread - It can be calculated with the following formula:
(2 x 17.33 cm) + (1 x tread) = 64
Each tread will be computed as 29.34 cm
The consequential staircase will contain 15 steps of 29.34 cm of tread and 17.33 cm of riser.
Based on the use and local regulations, there should be a minimum width of 80 cm for stairs in single-family homes, and more than 1.00 meters in public buildings.
Preferably, a stairway shouldn't contain in excess of 15 steps in a row. After 15 steps, a landing should be arranged. It's suggested that a landing is calculated minimum the same as 3 treads.
The height among the steps and the ceiling should remain 2.15 meters at minimum. The height of the handrail differs among 80 and 90 cm from each step.
Some vital guidelines for measuring staircase dimensions and designs
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Wednesday, April 25, 2018

Steps to work out road filling in hilly area

S.L. Khan, the eminent civil engineer, presents another informative construction video tutorial where he briefly explains the process for working out the road filling in hilly area.

In this video, solution is given to the following examples :-


Examaple 1


With specified cross section of road in hill area, work out the quantity of earth work in banking toward the length of 100 ft.


Suppose the permission rate of the road is taken as breadth of the road and it is 32 feet. The half of it is 16 feet. The mean depth of the filling is taken as 1.85 feet. The side slope is taken as 2:1. The cross slope is taken as 10:1.


Based on the above data, the quantity of earth work in banking will be determined.


To obtain the total filling of this section, apply the following formula :-


Filling = Cross Section Area x Length


To learn rest calculation process, go through the following video tutorial.




~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~