Friday, February 16, 2018

What are the exact room sizes, basic needs and vastu position of any Indian residential building?

To sustain a convenient and healthful life, the room space in the house should be used in an efficient manner. So, you should have sufficient knowledge on lowest room size, basic needs and exact position of various rooms in the conventional Indian residential building which are based on day-to-day activities in the household, sun’s location, privacy and grouping of rooms for smooth access and Vastu Sastra preference for house.

In this article, you will get all the details of the above mentioned topics :-

Living Room: Living room is located in the entrance of the house. It has direct connectivity with other rooms like kitchen, bedroom, staircase and bathroom.


In this place all the family members frequently meet. So, there must be adequate natural lighting and air circulation via large windows. The facing of windows should be in east and north direction to arrange sufficient lighting and ventilation.

Least room size for living room= 16 sq.m with 3m on one side.

Position, direction for living room with adherence to Vastu Sastra = North-East (Eshanya = Direction of health, power and prosperity)

Bed Room: Bed room is treated as the private rooms for family members where they perform different activities. Master bedrooms involve attached bathroom and toilet. Privacy is a great concern for this room. These rooms are frequently utilized in the night-time and early morning hours and so their facing should be in south direction or North-East direction to experience direct sunlight and heat in the early morning hours.

Least room size of bedrooms= 12 sq.m

Position, direction for Bedroom as per Vastu Sastra = South direction (Dhakshin Yama = Direction of health, happiness, growth and female love). Keep away from North-West direction.

Also, sleep with head facing south direction because earth magnetic influence.

Kitchen: Kitchen should be built up on the North-East or South-East direction with windows facing East. Modern kitchen should be constructed with shelves, loft, sink, storage and exhaust. It should be open and smoothly approachable to the living room and dining area to track the activities as well as keep in contact with other members in dining.

Least room size for kitchen = 8 sq.m

Position, direction for Kitchen with adherence to Vastu Sastra = South-East direction with cooking faces east (Agneya or Agni = Direction of health)

Agni mulai as per vastu sastram of tamilnadu
Next option is North-West direction(Vayavya or Vayu)
or finally North-East Direction (Eshanya)
Staircase
Required area of the staircase is based on the type and position of the staircase.
Least width of steps = 1 m
Landing size = 1.2 m
Rise = 150 to 180 mm
Tread = 250 to 300


Position, direction for staircase as per Vastu Sastra = South or South-West direction.

To get more information on the above topics, go through the following construction article civilrnd.com

What are the exact room sizes, basic needs and vastu position of any Indian residential building?

~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~

Thursday, February 15, 2018

Structural Design – Minimum Standard

Thumb rules for Structural Design of RCC Structures: It is advisable to use superior structural design software like ETabs or Staad Pro for making the design of structures. There exist different types of variables in making the design of a structure and therefore no minimum standards are perfect.

This guide is very helpful for making the design of very small structures, as for instance up to G+1 floors. It is recommended to apply good software for structural designer instead of manual methods. Manual method is only applicable for checks.

Real design is accomplished by applying the computers, through very advanced design concepts like pushover analysis, seismic analysis, wind loads simulation and various advanced processes.

Design of RCC Structural Components: This construction article sheds light on the minimum standards that should be undertaken for making the design of RCC structural components of a structure, like columns, beams, slab and foundation. Besides, the explanation is also provided for the minimum safe standards for the reinforcing bars which should be employed for the design of the above mentioned Structural Components.

Minimum cross-sectional dimension for a Column is 9”x 9” (225MM x 225MM). But to get rid of slenderness issues, a rectangular column with dimension 9″x 12″ (225 MM x 300 MM) should be designed for maintaining safety.

It is recommended to utilize M20 grade concrete for construction as per IS 456:2000 standard. The minimum steel required in a 9″ x 9″ column is 4 bars of 12 MM containing stirrups of 8 MM steel rings at a gapping of 150 MM centre to centre.

In a 9″ x 12″ column, two more bars should be included to easily manage the total to 6 bars having 12 MM diameter. This design is trustworthy for up to G+1 floors.

Minimum RCC beam size should not be under 9″x 9″(225MM X 225MM), with an extra slab thickness of 125 MM. It will be perfect to apply a minimum of 4 bars, with 2 bars having 12 MM thickness in the bottom of the beam, and 2 bars having 10 MM at the top of the beam.

A concrete cover having 40 MM dimension should be used. Besides, M20 grade of concrete (1 part cement : 1.5 parts sand : 3 parts aggregate : 0.5 parts water) should also be used.

Minimum thickness of RCC slab should be 5″ (125MM) as a slab may comprise of electrical pipes which are implanted into them with 0.5″ dimension or more for internal wiring to significantly decreases slab depths at specific places. It leads to cracking, weakening and water leakage throughout rains. Therefore, a minimum thickness of 5″ should have been retained.

Minimum size of foundation for a single storey of G+1 building should be 1m x 1m, where safe bearing strength of soil is 30 tonnes per square meter, and the approaching load on the column does not surpass 30 tonnes. Minimum depth of footing should be 4′underneath ground level. It is suggested to go to depths up to had strata.

To get more information, go through the following link www.civilprojectsonline.com