adsense analytic

Tuesday, February 11, 2020

Download some crucial civil engineering journals with most updated information

Go through the huge lists of civil engineering journals which are very useful for civil engineers to be updated with the most recent advancement in civil engineering fields.
The journals include original papers inside the extensive field of civil engineering which focus on the following topics :-
Download some crucial civil engineering journals with most updated information
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Monday, February 10, 2020

Using Light Gauge Steel Frames in Construction

There is a new construction method on the market, and it is quite cool. Called the Light Gauge Steel Frame Construction, it is successfully replacing the standard wood frame construction method. This innovative method is being widely accepted in many building designs and construction aspects.
The Light Gauge Steel Frames offer several advantages. Some of them are design flexibility, strength, sustainability, buildability, etc. This makes Light Gauge Steel Frames easier to build and much safer too. Not only that, it is also faster to build. Word to the wise, though - the light steel frame is susceptible to fire, so fire protection coating needs to be provided.
Based on ASTM standard A1003, Light Gauge Steel Frames are manufactured from structural steel sheets. These sheets are formed into ‘C’ ‘Z’ and ‘S’ shapes. This makes the structure strong and able to support heavy loads. It is also called cold formed steel. This is because of the process by which it is manufactured.
This added strength and flexibility leads Light Gauge Steel Frames to support increased spans. They can be shaped into custom openings. Moreover, they can support many different types of external facade treatments. This sheer versatility is making the Light Gauge Steel Frames very popular among modern constructors.
One thing to be noted about Light Gauge Steel Frames is they are much more susceptible to corrosion effects than standard wooden frames. For this reason, they have to be provided with zinc, aluminum or combo coatings to make them corrosion-resistant over long periods.
Using Light Gauge Steel Frames in Construction
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Saturday, February 8, 2020

External Plastering Work Checklist - To follow in Building Construction

The external plastering work in a building project is a pretty important work because it provides the outer finish of the building. Not only that, it is the foundation for the building’s aesthetics. For these reasons, every constructor should keep in mind some basic steps in order to do it right. As such, the following checklist can be very helpful in external plastering work in building construction.
1. Clean the surface: Make sure that the external surface of the building is clean. That means the block or brick masonry and concrete surface. These should be clear of dust, oil grease, loose materials, mortar dropping, nails, wood, metal strips, etc. You should have an even, smooth surface to work on. Otherwise the bonding will not work.
2. Make scaffoldings: You need to erect a scaffolding in order to reach the entire outside surface. Conversely, you might be needing a double scaffolding as well. You have to do this without making a hole in the wall. Since in this phase you must not damage the wall in any way. However, if authorities permit, you can take support from other parts of the building.
3. Mortar and socketing: The gaps between the masonry and the beams that show on the outside needs to be filled with rich mortar. Also, you need to finish out the socketing works.
4. Chicken mesh: Then, fix a chicken mesh on the joint of RCC and masonry wall. The mesh should be 6 inches wide. Nail this mesh at 230mm intervals only.
5. Plumb measure: Use the plumb (also the line) from top to bottom to ensure the accuracy of the plastering.
The plastering here should be of a single coat of 10-12mm only. Also, you must check all the edges.
6. Handle jutting out stuff: Sometimes, a beam or a column, or other parts of construction may be budging out of the plastering. In this case, first take approval of the designer to see if you can break it off. If you can, then use a sharp chisel or hammer to break off the jutting-out portion. Also, you can use a concrete breaker in this. Do take care that it doesn’t hurt any other part of the building.
External Plastering Work Checklist - To follow in Building Construction
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Friday, February 7, 2020

How to avoid Honeycombing in RCC Structures

Definition of a honeycombing: Honeycombing refers to a structural fault in a RCC Structure. Honeycombed surface is the areas of the concrete surface where the coarse aggregate are eminently observable.
If precaution is not taken for honeycombed surface, the RCC structure fails to achieve optimal performance according to its design (structurally weak). Besides, it also lets damaging agents like contaminated water and air entering through the produced voids which can impact the strength of structure considerably.
Causes for Honeycombing: Honeycombing in RCC Structure is happened because of the following reasons -
1. Concrete mix is not homogenous.
2. The applicability of concrete is inadequate and not matched with its placement need.
3. Inadequate compaction to concrete.
4. Concrete flow is not dispersed to all corner due to steel congestion.
5. Concrete is set afore time prior to placing.
6. High free fall of concrete, at the time of pouring
7. Form work is not waterproof or inflexible.
8. Incorrect detailing and/or fixing of steel
How Honeycombing in Concrete can be avoided?
Check concrete production/cohesiveness from time to time to organize all concrete batches.
Tip: If it is possible to create ?ball? from the fresh concrete, a cohesive concrete mix is produced.
Concrete workability should tally with the placement need. As for example, a lightly reinforced column should contain 75mm slump, a heavily reinforced column may require 150mm slump.
Make sure that the compaction of placed concrete is perfect, vibrators should have been detached as big air bubbles stops to come out (over vibration can lead to bleeding). Various sizes (25mm, 40mm, and 60mm) of vibrator needle should have been utilized according to RCC sections.
How to avoid Honeycombing In RCC Structures
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Tuesday, January 28, 2020

Standard Staircase Dimensions in Buildings

Functioning as a system of steps leading people from one level of the building to another, a staircase is a pretty complex building element. This is because staircases have particular geometry and function. Everything about this building element needs to be carefully planned because of that.
The dimensions of the steps and regulations of the heights and widths of the steps need to be carefully maintained. Not only that, you need to pay attention to the material being used as well.
In this article we will discuss the standard staircase dimensions today.
In staircase design, concrete offers great reliability in terms of load-bearing and production benefits. Geometry requirements, heat resistance and tensile strength, all can be fulfilled by using concrete. The staircases that are made of in-situ concrete can be adapted to any building plans on site.
On the other hand, precast staircases are not as flexible and can only be fitted into predefined design dimensions specific for that staircase design.
However, one advantage of using precast staircases is that they can be produced efficiently, faster and more cleanly than in-situ staircases.
It goes without saying that special attention must be paid to the basic dimensions of the stair breadth and rises. You should also need to take care of dividing the staircase with proper landings in order to enable resting places in a long climb. The number of steps without an intermediate landing should be counted in this matter.
Staircase dimensions are an important part of staircase safety. This page covers all of the important staircase measurements and a mistake to watch out for.
Staircase design has to account for the human step sizes and the comfortable distance a human foot can travel vertically.
The tread size is dictated by the average adult foot size. Though it is not necessary to fit your entire foot on the stairs, it should be kept as close as possible in order to keep it as safe as possible. The standard tread size is 10 inches minimum, or 25.4 centimeters.
Standard Staircase Dimensions in Buildings
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Pier foundation and their types, advantages

A pier is kind of a big brother to a column. It is a support structure holding up great loads, and can take a lot of tensile strains as well. Piers are constructed in a dry place by digging out the soil in a large diameter hole and then filling it with reinforcements and concrete. A pile greater than 0.6 meter in diameter becomes a pier.
The pier foundation transfers the load on the pier to the ground via the bearing. It is generally a shallow structure placed on top of sound rock layer. Hard soil is also good for pier foundation construction provided they can take the load.
Types of Pier Foundation
There are two main types of pier foundations, namely:
1. Masonry or concrete pier
2. Drilled caisson
Which type of pier foundation will be used depends upon the depth of the hard bed, nature of soil, and the superimposed load.
Masonry or Concrete Pier Foundation
The name comes from the pier being made of concrete. Precast sections are manufactured in-situ or in facility. Then they are driven into the ground at location. The sections are generally reinforced with steel wires. At the bottom, a cast steel shoe is provided to hold the structure better and to transfer the load well. The cross sections of these piers are generally no more than 30-50 centimeters and they are no taller than 20 meters.
Drilled Caisson Pier Foundation
A drilled caisson is a large compressed member subjected to an axial load. The load is at the top and the reaction is at the bottom. These can be concrete caisson with enlarged bottom, a steel pipe caisson with concrete filled in it, or a concrete body caisson with a steel pipe core.
Pier foundation and their types, advantages
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~

Friday, January 24, 2020

How to find out the number of tiles required for a floor

In this construction video tutorial, you will learn how to compute quantity of tiles required in building rooms or bathrooms.
Initially, you have to determine the area of the room where the tiles will be placed.
Suppose, there is an L-shaped room and it is divided as part A and part B.
Length of room A = 3 meter
Breadth of room A = 2 meter
Length of room B = 6 meter
Breadth of room B = 2 meter
At first, calculate the area of A as follow :-
Area = Length x Breadth
After putting the above values of room A, we get
Area = 3 x 2 = 6 square meter
Then, calculate the area of B as follow :-
Area = Length x Breadth
After putting the above values of room A, we get
Area = 6 x 2 = 12 square meter
Therefore, total area = area of A + area of B = 6 + 12 = 18 square meter
Suppose the length of one tile = 600 mm = 0.6 m and breadth = 600 mm = 0.6 m
So, area of one tile = length x breadth = 0.6 x 0.6 = 0.36 square meter
There, no. of required tiles = Total Area / Area Of One Tile = 18 / 0.36 = 50 Nos. (approx)
How to find out the number of tiles required for a floor
~~~~~~~~~~~~~~~~~~~~~~~~~~
Published By
Rajib Dey
www.constructioncost.co
~~~~~~~~~~~~~~~~~~~~~~~~~~